MODULE - I
Fire Extinguishers:
- Types of Fire extinguishers
- Selection of Fire Extinguishers
- Design Method & Distance Between Extinguishers.
- Type of approvals on fire extinguishers.
- Installation procedure.
- Maintenance procedure.
MODULE - II
Sprinkler System:
- Sprinklers Operation procedure & Types
- Pendent Type sprinkler.
- Recessed Pendent type sprinkler.
- Concealed type pendent type sprinkler.
- Sidewall Type sprinkler.
- Pipe sizing Calculation.
- Type of pipes used.
- Sprinkler flow calculation.
- Sprinkler coverage Distance.
- Type of approvals on fire extinguishers.
- Installation procedure.
MODULE-III
Wet Riser & Dry Riser System- Cabinet System:
- Cabinet Types & Selection.( Surface type & Recessed Type)
- Landing Valve Selection.
- Hose Reel Selection.
- Pipe sizing Calculation.
- Type of pipes used.
- flow calculation.
- coverage Distance Between Hoses.
- Type of approvals.
- Installation procedure..
MODULE - IV
Fire Pump System:
- Types of Fire Pump Set.
- Electrical Pump
- Diesel Pump
- Jockey Pump selection
- Suction side valve selection
- Discharge side valve selection
- Pump Head flow calculation
- Pump flow Calculation
- Control panel selection
- Pressure Gauge Operation
- Pressure switch Operation
- Flow meter Operation
- Test Line Sizing
- Delivery Head Sizing
- Pump Plinth Sizing
- Operation Procedure of fire pump set
- Pump Room Sizing
- Hydraulic calculation
- Pipe sizing Calculation
- Type of pipes used
- Type of approvals.
- Installation procedure.
- Maintenance procedure.
MODULE - V
Deluge system:
- Deluge valve selection
- Mechanical type operation
- Electrical type operation
- Deluge valve Operation
- Pipe sizing Calculation
- flow calculation
- Installation procedure
MODULE - VI
Deluge Foam system:
- Deluge Foam valve selection
- Mechanical type operation
- Electrical type operation
- Foam Tank sizing
- Type of Foam Used
- Concentration of Foam Selection
- Pipe sizing Calculation
- flow calculation
- Operation method of Foam
- Installation procedure
MODULE -VII
FM200 System / Novec 1230 / Inergen System:
- Design density calculation
- Cylinder Selection
- Gas Quantity calculation
- Type of gases Used
- Electrical type operation
- Detection System
- Fire suppression panel
- Manual Call station
- Abort Switch
- Solenoid valve operation
- Coverage area of Nozzle
- Manifold selection
- Pipe sizing Calculation
- flow calculation
- Operation method
- Installation procedure.
MODULE -VIII
Fire alarm system:
- Fire alarm panel selection
- Loop Card selection
- Network card selection
- Smoke detector
- Heat Detector
- Multi-sensor Detector
- Manual call point
- Sounder w/ flasher
- Sounder w/ flasher weather proof
- Duct Detector
- Flame Detector
- Linear heat detector
- Cable selection
- Coverage area of Devices
- Operation method
- Installation procedure
MODULE - IX
Emergency Lighting system:
- Panel Capacity selection
- Self-contained Type
- Monitoring type
- Central battery type
- Battery calculation
- Loop Card selection
- Network card selection
- Emergency Light & Watt selection
- Exit Light & Watt selection
- Cable selection
- Coverage area of Devices
- Operation method
- Installation procedure
MODULE - X
Voice evacuation system & Public Address system:
- Panel Capacity selection
- Ceiling mounted speaker
- Wall mounted speaker
- Amplifier calculation
- Wattage calculation
- Cable selection
- Coverage area of Devices
- Operation method
- Installation procedure
Examination:
Written examination ( 3 hours)
Pass grade: 50% pass
60% merit
80% Distinction